10 Prototype boards with red front panels were manufactured in early 2009. These boards are not identical to the production boards because they have a smaller FPGA. The production front panels are marked "DCC2" and are black.

Boards are numbered in decimal starting with 2001 for the first prototype up to a maximum possible number of 2255. The first digit is always '2'. The other three digits represent the decimal equivalent of the binary value set by cutting jumpers on the PCB.

You can find out which board is where in the pit as follows:

(log on to a head node, i.e. cmsusr1 etc)

$ cd ~ehazen/GetStatus
$ ./getAllVersions.sh | ./parseVersions.pl

 Crate  Bus    Slot   Xilinx     LRB        VME    S/N  FED
 ====================================
     4  caen:0 10     0x3018     0x010a     0x0104 2001 700
     4  caen:0 20     0x3018     0x010a     0x0104 2002 701
     0  caen:1 10     0x3018     0x010a     0x0104 2174 702
     0  caen:1 20     0x3018     0x010a     0x0104 2176 703
       .... remainder of list truncated ...

Here is Dick Kellogg's list which may become the official one. For now, you have to check both.

Prototype Boards

S/N Location Notes
2001 904 Tested in MWGR 15
2002 904  
2003 904  
2004 904  
2005 BU - Test stand  
2006 Whitman To be destructively tested for soldering temperature profiles
2007 BU Ethernet resistor replaced - re-test
2008 BU Ethernet resistor replaced - re-test
2009 BU Tested. No errors
2010 BU  

Production Boards

The production board serial numbers start with 2129 as shown below. On the PCB, the binary "jumpers" (actually cut traces) start with "10000001".

Note that you can sort the table below by clicking the column headings. Sort by Location for an easy way to check how many boards are where.

S/NSorted ascending Location Notes Date shipped Status
2129 FED_730 Tested. 5/26 OK
2130 *904 Hospital Orbit number mismatches as FED 731 01-jul-2009 (removed) 5/26 Sick
2131 FED_720 Tested. 5/26 OK
2132 FED_718 Tested. 5/26 OK
2133 904 Hospital Removed due to CRC errors during intervention on other DCC issues. Suspect spurious issue: http://cmsonline.cern.ch/cms-elog/637389 3 Aug 2011 OK
2134 BU Returned to BU because of alleged mis-matches 5/26 Sick
2135 FED_724 Tested. HTR13 LED broken. Now fixed. 5/26 OK
2136 BU Shipped back to BU 6/9/09 per dick to CERN 5/26 OK
2137 FED_725 Tested. Initially 2 errors. 2nd time tested-no errors. Probably a wiring issue. 5/26 OK
2138 FED_726 Tested. 5/26 OK
2139 FED_716 Installed on 3 Aug 2011 http://cmsonline.cern.ch/cms-elog/637389 3 Aug 2011 OK
2140 FED_728 Tested. Initially 2 errors. 2nd time tested-no errors. Probably a wiring issue. 5/26 OK
2141 FED_723 Tested. 5/26 OK
2142 FED_701 Prior incident as different FED (3/24/10): Was removed when we had an issue where no HTRs were sending data. No other symptoms point to DCC failure 6/11/10 OK
2143 CERN Tested. Ethernet error(RJ 45). Was not fixed. Returned to BU 6/9/09. Tested/shipped back to CERN 8/18/11 OK
2144 FED_722 Tested. 5/26 OK
2145 904 Spares "Stops sending events down SLINK and goes to OFW at 80 kHz" . Tested OK by PDL 4/1/11 11/16 OK
2146 BU Tested. Pin9 of HTR14 RJ45 to U14 line open. Could be a PCB problem.   Sick
2147 BU Tested. Two broken LEDs, Ethernet error(RJ 45), and CRC error. R25 cold solder,D25 is also missing. Errors fixed as of 6/3   OK
2148 FED_721 Tested. 5/26 OK
2149 BU Tested. U0 soldering problem(most likely because U10 looks OK) Multiple lines to U10 without connection   Sick
2150 FED_719 Tested. 7/1 OK
2151 FED_712 Tested. 6/1 OK
2152 904 Hospital CRC Errors in Event Builder but not LRB. All errors from single LRB chip. See details below 6/11/2010 Sick
2153 FED_710 Tested. 6/1 OK
2154 FED_704 Installed on 12 Jul 2011 12 Jul 2011 OK
2155 FED_729 Installed on 3 Aug 2011 http://cmsonline.cern.ch/cms-elog/637389 3 Aug 2011 OK
2156 FED_714 Tested. 6/1 OK
2157 *CERN Tested. Warped board 6/1 OK/warped
2158 BU Problem: DSP FW version 0x301c reports as version 0x0 on this board. Can program manually with DCC2Tool.exe w/o issues. CRC of DSP FW reported by DCC2Tool.exe is correct. 6/1 (returned) Sick
2159 FED_713 Tested. 8/18/11 fail LRB4 test, however, this LRB is not in use (no spigots attached to HTRs) 6/1 LRB4 sick
2160 904 Hospital Removed from FED 700 due to UERR on spigot 13 - 10/29/09. 6/1 Sick
2161 FED_708 Tested. 6/1 OK
2162 904 Hospital 3 Aug 2011: Removed because it is not sending events over VME. Perhaps DAQ software issue? http://cmsonline.cern.ch/cms-elog/637389 6/1 OK
2163 BU DDR memory chip replaced 2 Aug 2011 OK
2164 FED_715 Tested. 6/9 OK
2165 FED_711 Tested. 6/9 OK
2166 FED_731 Tested. 6/9 OK
2167 BU Tested. Spigot CRC error/SLINK error   Sick
2168 FED_707 Tested. 6/9 OK
2169 FED_706 Tested. 6/9 OK
2170 BU Tested. CRC errors. Spigot zero bad?   Sick
2171 FED_717 Tested. 6/9 OK
2172 904 Hospital CRC errros on LRB FPGA serving spigots 12,13,14. Elog: http://cmsonline.cern.ch/cms-elog/605813
Replaced LRB4 @ CERN shop. All FW in FLASH except VME FW corrupted. Now fails memory test on LRB2? Elog: http://cmsonline.cern.ch/cms-elog/689158
5 Oct 2011 Sick
2173 FED_705 Tested. 6/9 OK
2174 FED_702 Tested. 6/9 OK
2175 CERN Tested. Broken LED-->VME. Declared good, shipped to CERN 8/18/11 OK
2176 FED_727 31 July 2011: Removed from FED 703 due to BcN mismatch problems. This occurred during ramping and is likely not an actual DCC issue: http://cmsonline.cern.ch/cms-elog/631675
3 Aug 2011: Installed as FED 727 http://cmsonline.cern.ch/cms-elog/637389
3 Aug 2011 OK
2177 FED_709 Tested. 7/1 OK
2178 FED_700 Tested. Installed to replace 2160 - 10/29/09 7/1 OK
2179 FNAL Tested. Ship to FNAL 2011-05-12 OK
2180 BU Tested. TTS link error. SLINK error.   Sick
2181 904 Hospital CRC erros and "miscellaneous errors" during intervention on a different DCC problem: http://cmsonline.cern.ch/cms-elog/637389 3 Aug 2011 Sick
2182 *CERN Tested. 7/1 OK
2183 BU Tested. Ship to MN 2011-05-12 OK
2184 BU Tested. CRC error, SLINK error. "event size of 4800 words is unreasonable"   Sick
2185 CERN Tested. Shipped to CERN 8/18/11 OK
2186 CERN Tested. Shipped to CERN 8/18/11 OK
2187 BU Board is warped. won't fit into crate.   Sick
2188 BU Tested. Ethernet RJ45 error.   Sick
2189 CERN Tested. Shipped to CERN 8/18/11 OK
2190 CERN Tested. 1/10 OK
2191 CERN Tested. 1/10 OK
2192 CERN Tested. 1/10 OK
2193 BU Returned ~3/10/10 w/ spigot 3 problem (CASTOR) 1/10 Sick
2194 BU Tested. 3/11/11 -- problems with spigots 3-5 (Eric/Dick) Sick
2195 CERN Tested. Shipped to CERN 8/18/11 OK
2196 CERN Tested. Shipped to CERN 8/18/11 OK
2197 BU Tested.   OK
2198 BU Not ever tested?   ?

Changes:

S/N 2159 fails LRB4 link/memory test in the pit as FED 713. PDL discovered that these spigots are not in use on this FED and opted not to swap out.

-- EricHazen - 18 Aug 2011

S/N2163 LRB0 memory chip replaced. OK now. -- Main.Shouxiang Wu - 2 Aug 2011

S/N 2172 showed CRC errors on LRB FPGA serving spigots 12,13,14. Replaced in USC on 12 Jul 2011. Installed in 904 and powered up to find all LRB chips reporting appropriate FW versions.

-- PhilLawson - 19 Jul 2011

Ship 2179 and 2183 to FNAL and MN, respectively. Track# 1Z0159190193593478 and 1Z0159190190690681

-- EricHazen - 12 May 2011

Phil tested SN 2145 at CERN as follows:

Installed HCAL DAQ version 10.4.6 (unrelated, needed for different test)
Altered FedkitTest_LTClistenToTTS_from_slot20 to take SLINK data from slot 20.
Blasted high rate events at DCC. Due to SLINK readout (with only CRC error checking), 
  effective rate was limited to 34 kHz since this DCC was providing TTS signal.
Readout 10E6 events at this rate with no SLINK errors. Good enough for me.

-- PhilLawson - 24 Jan 2012

  • Replaced line for 2151. This was accidentally removed during an edit a long while back. Good thing for twiki history!

-- EricHazen - 01 Apr 2011

-- PhilLawson - 26 Jan 2011

  • Updated list to reflect install of SN 2141 as FED 701 to replace sick DCC SN 2152.
    • SN 2152 evidenced communication problems between LRB and Event Builder chip
    • Details in eLog: 402680 on June 7 2010

-- PhilLawson - 11 Jun 2010

  • Updated list to reflect swap of SN 2142 as FED 727

-- PhilLawson - 13 Apr 2010

  • Updated list per inventory from Dick. Location with * were confirmed at CERN per Dick's 12/14/09 inventory.

-- EricHazen - 14 Dec 2009

  • Check and update a few mistakes in the list of installed DCC2

-- EricHazen - 11 Dec 2009

  • FED 719 (S/N 2145) was consistently going to OFW at 80 kHz. No events being sent down SLINK. Replaced DCC with S/N 2150

-- PhilLawson - 16 Nov 2009

  • Logged in today and found FED 700 is now S/N 2160 (was previously 2001), FED 701 is now S/N 2152 (was previously 2002)
  • Problem with FED 710 & DSP FW 0x301c described above.