Difference: AMC13DebugLog (63 vs. 64)

Revision 6424 Jun 2013 - BenjaminBDickens

Line: 1 to 1
 
META TOPICPARENT name="CmsSlhc"
Please log AMC13 test activity below, blog style (new entries at top)
Added:
>
>

2013-06-24, dickens, dzou

  • Measured the temperature of the U2 chip on T1 before, during, and after the start up of AMC13 SN 33. This provides the operating range for future, temperature-controlled tests. Notes on setup:
    • U2 covered in heat sink compound and held in thermal contact with thermistor
    • Thermistor connected to arduino provides temperature readout which goes to laptop

Data sheet:

tempU2_1.jpg

  • ***Notes on data:
    • thermistor place in contact with chip at ~20 s
    • AMC13 booted on at ~70 s
    • bump in data from ~240 s to ~290 s due to loss of thermal contact
    • AMC13 turned off at ~370 s

 

2013-06-19, dzou, hazen

  • Move probe to CLK output of ADN2814 CDS
Line: 1037 to 1057
 It works! Now the AMC13 seems to be up and running with the MCH.

-- EricHazen - 02 Dec 2011

Added:
>
>
META FILEATTACHMENT attachment="tempU2_1.jpg" attr="" comment="" date="1372112366" name="tempU2_1.jpg" path="tempU2_1.jpg" size="53300" stream="tempU2_1.jpg" tmpFilename="/usr/tmp/CGItemp56673" user="dickens" version="1"
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.