2016-03-02, hazen

Checking on MultiFED readout software. Tried first with test version 0x24a in S/N 161 and it behaved badly. Reprogramming now to HCAL 0x4043. Test seq:

  daq 2
  wv CONF.EVB.ENABLE_DAQLSC 0     # turn off actual fiber output
  en 1,7 f t
  lt 5 100
  st
  re

This "works" but only one monitor buffer is read, not the two as expected. Not sure what I'm doing wrong. Diving into the code.

 

2016-02-18, dgastler

Update on writing to disk. It appears that data writing to disk is working better now with ~15kHz of 1952byte events going to disk (30MBps).
 