10 Prototype boards with red front panels were manufactured in early 2009. These boards are not identical to the production boards because they have a smaller FPGA. The production front panels are marked "DCC2" and are black.
Line: 53 to 53
 
2130 P5 Spares 1 July 2009: Orbit number mismatches as FED 731 (removed)
31 July 2011 Installed as FED 703
31 July 2011 OK
2131 FED_720 Tested. 5/26 OK
2132 904 Hospital 23 Jan 2012: Removed because we were not receiving any events over VME in local run. Possible software issue: http://cmsonline.cern.ch/cms-elog/750159 23 Jan 2012 Sick
Changed:
<
<
2133 904 Hospital Removed due to CRC errors during intervention on other DCC issues. Suspect spurious issue: http://cmsonline.cern.ch/cms-elog/637389
31 Jan 2012: Fails LRB memory test on LRB2, LRB3
31 Jan 2012 Sick: Bad Memory
>
>
2133 904 Hospital Removed due to CRC errors during intervention on other DCC issues. Suspect spurious issue: http://cmsonline.cern.ch/cms-elog/637389
31 Jan 2012: Fails LRB memory test on LRB2, LRB3. Repaired, test ok 2012-03-06
31 Jan 2012 OK
 
2134 BU Returned to BU because of alleged mis-matches 5/26 Sick
2135 FED_724 Tested. HTR13 LED broken. Now fixed. 5/26 OK
2136 BU Shipped back to BU 6/9/09 per dick to CERN 5/26 OK
Line: 70 to 70
 
2147 BU Tested. Two broken LEDs, Ethernet error(RJ 45), and CRC error. R25 cold solder,D25 is also missing. Errors fixed as of 6/3   OK
2148 FED_721 Tested. 5/26 OK
2149 BU Tested. U0 soldering problem(most likely because U10 looks OK) Multiple lines to U10 without connection   Sick
Changed:
<
<
2150 904 Hospital Developed memory problems on LRB2 (spigots 6,7,8) during the Dec 2011 shutdown: http://cmsonline.cern.ch/cms-elog/750642 24 Jan 2012 Sick: bad memory
>
>
2150 904 Hospital Developed memory problems on LRB2 (spigots 6,7,8) during the Dec 2011 shutdown: http://cmsonline.cern.ch/cms-elog/750642. Repaired, test ok 2012-03-06 24 Jan 2012 OK
 
2151 FED_712 Tested. 6/1 OK
2152 904 Hospital CRC Errors in Event Builder but not LRB. All errors from single LRB chip. See details below
While it would be good to run the memory test on this guy, the symptoms are not classic DRAM failure http://cmsonline.cern.ch/cms-elog/402680
31 Jan 2012: Passes LRB, DSP memory tests in 904. Good board? Worth testing at P5
6/11/2010 Sick
Changed:
<
<
2153 904 Hospital Developed memory problems on LRB3 (sp 9,10,11) during Dec 2011 shutdown. Removed on 24 Jan 2012 http://cmsonline.cern.ch/cms-elog/750642 24 Jan 2012 Sick: bad memory
>
>
2153 904 Hospital Developed memory problems on LRB3 (sp 9,10,11) during Dec 2011 shutdown. Removed on 24 Jan 2012 http://cmsonline.cern.ch/cms-elog/750642. Repaired, test ok 2012-03-06 24 Jan 2012 OK
 
2154 FED_704 Installed on 12 Jul 2011 12 Jul 2011 OK
2155 FED_729 Installed on 3 Aug 2011 http://cmsonline.cern.ch/cms-elog/637389 3 Aug 2011 OK
2156 FED_714 Tested. 6/1 OK
2157 *CERN Tested. Warped board 6/1 OK/warped
2158 BU Problem: DSP FW version 0x301c reports as version 0x0 on this board. Can program manually with DCC2Tool.exe w/o issues. CRC of DSP FW reported by DCC2Tool.exe is correct. 6/1 (returned) Sick
Changed:
<
<
2159 904 Hospital Tested. 8/18/11 fail LRB4 test, however, this LRB is not in use (no spigots attached to HTRs)
Developed memory issues on LRB1 (sp 3,4,5) over Dec 2011 shutdown. Removed on 24 Jan 2012: http://cmsonline.cern.ch/cms-elog/750642 Now LRB1 and LRB4 bad
24 Jan 2012 Sick: bad memory
>
>
2159 904 Hospital Tested. 8/18/11 fail LRB4 test, however, this LRB is not in use (no spigots attached to HTRs)
Developed memory issues on LRB1 (sp 3,4,5) over Dec 2011 shutdown. Removed on 24 Jan 2012: http://cmsonline.cern.ch/cms-elog/750642 Now LRB1 and LRB4 bad. Repaired, test ok 2012-03-06
24 Jan 2012 OK
 
2160 904 Spares Removed from FED 700 due to UERR on spigot 13 - 10/29/09.
27 Jan 2012: Cannot reproduce UErrs on lxcmdtest3 while running at 83 kHz. Board looks good
27 Jan 2012 Ok
2161 FED_708 Tested. 6/1 OK
2162 904 Spares 3 Aug 2011: Removed because it is not sending events over VME. Perhaps DAQ software issue? http://cmsonline.cern.ch/cms-elog/637389
26 Jan 2012: Tested on cmsmoe4 in 904. VME readout works just fine. Returning to pile of good spares
26 Jan 2012 OK
Line: 93 to 93
 
2170 BU Tested. CRC errors. Spigot zero bad?   Sick
2171 FED_717 Tested. 6/9 OK
2172 904 Hospital CRC errros on LRB FPGA serving spigots 12,13,14. Elog: http://cmsonline.cern.ch/cms-elog/605813
Replaced LRB4 @ CERN shop. All FW in FLASH except VME FW corrupted. Now fails memory test on LRB2? Elog: http://cmsonline.cern.ch/cms-elog/689158
5 Oct 2011 Sick: bad memory
Changed:
<
<
2173 904 Hospital CRC errors from LRB FPGA serving spigots 9,10,11. Elog: http://cmsonline.cern.ch/cms-elog/753520
Failes memory test on LRB3
24 Feb 2012 OK
>
>
2173 904 Hospital CRC errors from LRB FPGA serving spigots 9,10,11. Elog: http://cmsonline.cern.ch/cms-elog/753520
Failes memory test on LRB3. Repaired, test ok 2012-03-06
24 Feb 2012 OK
 
2174 FED_702 Tested. 6/9 OK
2175 CERN Tested. Broken LED-->VME. Declared good, shipped to CERN 8/18/11 OK
2176 FED_727 31 July 2011: Removed from FED 703 due to BcN mismatch problems. This occurred during ramping and is likely not an actual DCC issue: http://cmsonline.cern.ch/cms-elog/631675
3 Aug 2011: Installed as FED 727 http://cmsonline.cern.ch/cms-elog/637389
3 Aug 2011 OK
Line: 122 to 122
  Changes:
Added:
>
>
SN 2173, 2159, 2133, 2153, 2150 tested after repair -- EricHazen - 06 Mar 2012
 SN 2173 fails at P5. Tested with DCC2Tool.exe and it fails LRB3. Replaced with SN 2142 as FED 705. -- PhilLawson - 24 Feb 2012
 