Difference: DCC2BoardDatabase (26 vs. 27)

Revision 2713 Apr 2010 - PhilLawson

Line: 1 to 1
 
META TOPICPARENT name="DCC2Documentation"
10 Prototype boards with red front panels were manufactured in early 2009. These boards are not identical to the production boards because they have a smaller FPGA. The production front panels are marked "DCC2" and are black.
Line: 62 to 62
 
2139 *CERN Tested. 5/26 OK
2140 FED_728 Tested. Initially 2 errors. 2nd time tested-no errors. Probably a wiring issue. 5/26 OK
2141 FED_723 Tested. 5/26 OK
Changed:
<
<
2142 FED_727 Tested. 5/26 OK
>
>
2142 *904 Hospital Was removed when we had an issue where no HTRs were sending data. No other symptoms point to DCC failure 4/13/10 OK
 
2143 BU Tested. Ethernet error(RJ 45). Was not fixed. Returned to BU 6/9/09. Accidentally shipped 5/26 Sick
2144 FED_722 Tested. 5/26 OK
2145 *904 Hospital Stops sending events down SLINK and goes to OFW at 80 kHz 11/16 Sick
Line: 101 to 101
 
2178 FED_700 Tested. Installed to replace 2160 - 10/29/09 7/1 OK
2179 BU Tested.   OK
2180 BU Tested. TTS link error. SLINK error.   Sick
Changed:
<
<
2181 *CERN Tested. 7/1 OK
>
>
2181 FED_727 Tested. 4/13/10 OK
 
2182 *CERN Tested. 7/1 OK
2183 BU Tested.   OK
2184 BU Tested. CRC error, SLINK error. "event size of 4800 words is unreasonable"   Sick
Line: 123 to 123
  Changes:
Added:
>
>
  • Updated list to reflect swap of SN 2142 as FED 727

-- PhilLawson - 13 Apr 2010

 
  • Updated list per inventory from Dick. Location with * were confirmed at CERN per Dick's 12/14/09 inventory.

-- EricHazen - 14 Dec 2009

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2019 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.