Here is Dick Kellogg's list which may become the official one. For now, you have to check both.
 

Prototype Boards

S/N Location Notes
Changed:
<
<
2001 ??? Tested in MWGR 15
2002 ???  
2003 CERN - Bat 28 - cmsmoe6  
2004 CERN - Bat 904 - cmsmoe4  
>
>
2001 904 Tested in MWGR 15
2002 904  
2003 904  
2004 904  
 
2005 BU - Test stand  
2006 Whitman To be destructively tested for soldering temperature profiles
2007 BU Ethernet resistor replaced - re-test
Line: 47 to 50
 
S/N Location Notes Date shipped Status
2129 FED_730 Tested. 5/26 OK
Changed:
<
<
2130 904 Hospital Orbit number mismatches as FED 731 01-jul-2009 (removed) 5/26 Sick
>
>
2130 *904 Hospital Orbit number mismatches as FED 731 01-jul-2009 (removed) 5/26 Sick
 
2131 FED_720 Tested. 5/26 OK
2132 FED_718 Tested. 5/26 OK
2133 FED_729 Tested. 5/26 OK
Changed:
<
<
2134 CERN Tested. 5/26 OK
>
>
2134 BU Returned to BU because of alleged mis-matches 5/26 Sick
 
2135 FED_724 Tested. HTR13 LED broken. Now fixed. 5/26 OK
Changed:
<
<
2136 CERN Tested. 5/26 OK
>
>
2136 BU Shipped back to BU 6/9/09 per dick to CERN 5/26 OK
 
2137 FED_725 Tested. Initially 2 errors. 2nd time tested-no errors. Probably a wiring issue. 5/26 OK
2138 FED_726 Tested. 5/26 OK
Changed:
<
<
2139 CERN Tested. 5/26 OK
>
>
2139 *CERN Tested. 5/26 OK
 
2140 FED_728 Tested. Initially 2 errors. 2nd time tested-no errors. Probably a wiring issue. 5/26 OK
2141 FED_723 Tested. 5/26 OK
2142 FED_727 Tested. 5/26 OK
Changed:
<
<
2143 BU ? Tested. Ethernet error(RJ 45). Was not fixed. Accidentally shipped 5/26 Sick
>
>
2143 BU Tested. Ethernet error(RJ 45). Was not fixed. Returned to BU 6/9/09. Accidentally shipped 5/26 Sick
 
2144 FED_722 Tested. 5/26 OK
Changed:
<
<
2145 904 Hospital Stops sending events down SLINK and goes to OFW at 80 kHz 11/16 Sick
>
>
2145 *904 Hospital Stops sending events down SLINK and goes to OFW at 80 kHz 11/16 Sick
 
2146 BU Tested. Pin9 of HTR14 RJ45 to U14 line open. Could be a PCB problem.   Sick
2147 BU Tested. Two broken LEDs, Ethernet error(RJ 45), and CRC error. R25 cold solder,D25 is also missing. Errors fixed as of 6/3   OK
2148 FED_721 Tested. 5/26 OK
Line: 71 to 74
 
2151 FED_712 Tested. 6/1 OK
2152 FED_701 Tested. 6/1 OK
2153 FED_710 Tested. 6/1 OK
Changed:
<
<
2154 CERN Tested. 6/1 OK
2155 CERN Tested. 6/1 OK
>
>
2154 *CERN Tested. 6/1 OK
2155 *CERN Tested. 6/1 OK
 
2156 FED_714 Tested. 6/1 OK
Changed:
<
<
2157 CERN Tested. 6/1 OK
>
>
2157 *CERN Tested. Warped board 6/1 OK/warped
 
2158 BU Problem: DSP FW version 0x301c reports as version 0x0 on this board. Can program manually with DCC2Tool.exe w/o issues. CRC of DSP FW reported by DCC2Tool.exe is correct. 6/1 (returned) Sick
2159 FED_713 Tested. 6/1 OK
2160 904 Hospital Removed from FED 700 due to UERR on spigot 13 - 10/29/09. 6/1 Sick
Line: 94 to 97
 
2174 FED_702 Tested. 6/9 OK
2175 BU Tested. Broken LED-->VME.   Sick
2176 FED_703 Tested. 6/9 OK
Changed:
<
<
2177 CERN Tested. 7/1 OK
>
>
2177 *CERN Tested. 7/1 OK
 
2178 FED_700 Tested. Installed to replace 2160 - 10/29/09 7/1 OK
2179 BU Tested.   OK
2180 BU Tested. TTS link error. SLINK error.   Sick
Changed:
<
<
2181 CERN Tested. 7/1 OK
2182 CERN Tested. 7/1 OK
>
>
2181 *CERN Tested. 7/1 OK
2182 *CERN Tested. 7/1 OK
 
2183 BU Tested.   OK
2184 BU Tested. CRC error, SLINK error. "event size of 4800 words is unreasonable"   Sick
2185 BU Tested.   OK
Line: 119 to 122
 

Changes:

Deleted:
<
<
  • Logged in today and found FED 700 is now S/N 2160 (was previously 2001), FED 701 is now S/N 2152 (was previously 2002)
  • Problem with FED 710 & DSP FW 0x301c described above.
 
Changed:
<
<
-- PhilLawson - 26 Aug 2009
>
>
  • Updated list per inventory from Dick. Location with * were confirmed at CERN per Dick's 12/14/09 inventory.

-- EricHazen - 14 Dec 2009

  • Check and update a few mistakes in the list of installed DCC2

-- EricHazen - 11 Dec 2009

 
  • FED 719 (S/N 2145) was consistently going to OFW at 80 kHz. No events being sent down SLINK. Replaced DCC with S/N 2150

-- PhilLawson - 16 Nov 2009

Changed:
<
<
  • Check and update a few mistakes in the list of installed DCC2
>
>
  • Logged in today and found FED 700 is now S/N 2160 (was previously 2001), FED 701 is now S/N 2152 (was previously 2002)