Difference: DCC2BoardDatabase (22 vs. 23)

Revision 2316 Nov 2009 - PhilLawson

Line: 1 to 1
 
META TOPICPARENT name="DCC2Documentation"
10 Prototype boards with red front panels were manufactured in early 2009. These boards are not identical to the production boards because they have a smaller FPGA. The production front panels are marked "DCC2" and are black.
Line: 59 to 59
 
2142 FED_727 Tested. 5/26
2143 BU Tested. Ethernet error(RJ 45). Was not fixed. Accidentally shipped 5/26
2144 FED_722 Tested. 5/26
Changed:
<
<
2145 FED_719 Tested. 5/26
>
>
2145 904 Hospital Stops sending events down SLINK and goes to OFW at 80 kHz 11/16
 
2146 BU Tested. Pin9 of HTR14 RJ45 to U14 line open. Could be a PCB problem.  
2147 BU Tested. Two broken LEDs, Ethernet error(RJ 45), and CRC error. R25 cold solder,D25 is also missing. Errors fixed as of 6/3
2148 FED_721 Tested. 5/26
2149 BU Tested. U0 soldering problem(most likely because U10 looks OK) Multiple lines to U10 without connection
Changed:
<
<
2150 CERN Tested. 7/1
>
>
2150 FED_719 Tested. 7/1
 
2151 CERN Tested. 6/1
2152 FED_701 Tested. 6/1
2153 FED_710 Tested. 6/1
Line: 117 to 117
  EricHazen - 15 Apr 2009

Changes:

Changed:
<
<
Logged in today and found FED 700 is now S/N 2160 (was previously 2001), FED 701 is now S/N 2152 (was previously 2002) Problem with FED 710 & DSP FW 0x301c described above.
>
>
  • Logged in today and found FED 700 is now S/N 2160 (was previously 2001), FED 701 is now S/N 2152 (was previously 2002)
  • Problem with FED 710 & DSP FW 0x301c described above.
  -- PhilLawson - 26 Aug 2009 \ No newline at end of file
Added:
>
>
  • FED 719 (S/N 2145) was consistently going to OFW at 80 kHz. No events being sent down SLINK. Replaced DCC with S/N 2150

-- PhilLawson - 16 Nov 2009

 