Difference:
AMC13BoardDatabase
(104 vs. 105)
Revision 105
04 Jun 2014 -
DavidZou
Line: 1 to 1
META TOPICPARENT
name="HcalDTC"
Each AMC13 as shipped is a 3-board stack (T1, T2, T3). The serial number is set by soldered jumpers on the T2 board (8 bits). On
AMC13XG
the serial number is printed on the front panel label in decimal.
Line: 98 to 98
16
Tested OK
S=0xb V=0xf
UW
Shipped to MSN 7/25/12
daq@login.hep.wisc.edu
then
daq@ayinger.hep.wisc.edu
17
Tested OK
S=0xb V=0xf
UW
Shipped to MSN 7/25/12
18
Tested OK
S=0xb V=0xf
UW
Shipped to MSN 7/25/12
Changed:
<
<
19
Tested OK
S=0x17 V=0x2a
BU
Retest 8/31/12, productiontest errors 6/18/13
>
>
19
Tested OK
S=0x17 V=0x2a
BU
T1 has power supply problem (2014/06/04), productiontest errors 6/18/13, Retest 8/31/12
20
Tested OK
BU? Not in CMS Lab
Two more boards shipped to DESY and Rice in Nov 2012.